5 Transport and installation
Tab. 5
Number of pulses
Z pulse or 0 pulse
Power supply
Current consumption**
Max. load
Max. frequency**
Output voltage, high level**
Output current, high level**
Output voltage, low level**
Output current, low level**
Tab. 6
Ambient temperature
(operation, storage in a closed
environment)
Ambient temperature (transport)
Relative humidity
5 Transport and installation
The device is part of the MFS-V3 system and comes without a connector set and quick coupling.
6 Commissioning
Electric shock due to defective cables
Damaged or improperly installed cables can lead to fatal electric shock.
► Check all live cables and connections for proper installation and damage.
► Damaged, deformed or worn parts should only be replaced by a qualified electrician.
Risk of crushing
Limbs can be crushed if device components are improperly installed or uninstalled.
► Keep your hands out of the danger zone.
► Check and wear your personal protective equipment.
NOTICE
Risk of material damage due to improper transport and installation
Improper transport or installation may result in material damage and irreparable damage to the device.
► Protect the device against weather conditions, such as rain and direct sunlight.
► Use the device only in dry, clean and well-ventilated rooms.
► Attach the device to equipment or a robot, if necessary with an insulating plate.
► Position the robot so it can be easily mounted.
► Mount connections according to the selected welding system.
EN - 10
Encoder (wire actual value encoder)
Ambient conditions for transport, storage and operation
WARNING
WARNING
MF3-Laser Front/Rear
300
(Z) 1/revolution
4.5 to max. 30 V*
35 ± 3 mA
20/output mA*
200 kHz*
0.6–5 V
−25 mA
0–0.5 V
10 mA
0 °C to +50 °C
−20 °C to +70 °C
Up to 90% rel. humidity at +20 °C