Module - WEG CFW500-SFY2 Instrucciones Y Manual De Seguridad

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

F0160 - Safety Functions Module in Fault State
Description:
It indicates to the user that the safety functions module is in the fault state.
Possible Causes/Correction:
Incorrect installation of the safety input circuit.
Discrepancy between the safety inputs (STO1 and STO2) greater than 1 s.
Incorrect configuration of safety input type (dry contact or OSSD) on DIP switches S1.
Safety functions module programming DIP switches (S2) activated in operational state.
Incorrect programming of the safety function or programming timeout (2 min).
Electronic circuit of the safety functions module damaged.
F0161 - Safety Functions Module Communication Fault
Description:
It indicates to the user that the inverter has lost communication with the safety functions module.
Possible Causes/Correction:
Poor contact between the safety functions module and the frequency inverter.
Damage in the electronic circuits of the frequency inverter control or the safety functions

module.

Maintenance and Troubleshooting
CFW500 | 25

Publicidad

Tabla de contenido
loading

Tabla de contenido