en-us Installation
In-line blower
2.
In-line blowers can be mounted along the duct line
anywhere between the kitchen and the exterior wall, if
there is easy access to duct line, e.g. in an attic.
Remote and in-line blower motor wire connection:
3.
Remove junction box channel covering the wires.
‒
Remove one circular knockout.
‒
Route the blower motor's plug connector to the hood.
‒
Connect the blower's harness to the hood harness.
Route the blower harness through the self-locking
‒
clip.
Connecting the electrical wires
Notes
BSH is not responsible for wiring errors during
¡
installation. Installation wiring errors are not covered by
the Statement of Limited Product Warranty.
Refer to the wire diagram included with the appliance.
¡
Run a 120V AC, 15A circuit power cable from the
1.
service panel through the strain relief.
→ "Hanging the chimney wall hood", Page 15
18
Connect black wire to power supply black wire, white
2.
wire to power supply white wire and green wire to green
wire or bare wire.
A
White to white
B
Black to black
C
Green to green or bare wire
Place all wiring connections inside the junction box
3.
channel. Reinstall on the top plate. Ensure that the
wires are secure and that no wires are pinched.
Connecting the extension cable (optional)
EXTNCB25W 25 ft. remote and in-line blower extension
cable.
Parts included:
1.
– 25 ft. cable (1)
– Adapter cables (2) - not needed for all models
Route the hood's internal blower harness through the
2.
strain relief.