Connect the 25 ft. extension cable to the blower
3.
harness outside the hood.
A
Connects to the hood
B
Connects to a remote or in-line blower
Note: Cutting of the connector will void the warranty of
the appliance.
The blower extension cable is compatible with the
following in-line and remote blowers:
Blower
Remote blower
In-line blower
5.6 Make-up air damper relay switch
(optional)
Local codes may require the use of an additional backdraft
and/or make-up air damper. Contact your local HVAC
professional for specific requirements.
This hood provides a relay switch to connect a make-up
air damper (120V max). Installations will vary according to
the location in the home where the appliance is installed
and the damper used. Use the following illustration as
guidance for your installation. Always comply with local
code requirements.
Connecting the make-up air damper relay switch
Access the hood's wiring.
1.
Model
VTR2FZ
VTI2FZ
Route the make-up air damper harness through the
2.
strain relief to the terminal block.
The make-up air kit hot and return connections can
‒
use either terminal connection. There is no polarity
requirement for the two pin terminal block.
Secure the ground wire with the green T-20 ground
3.
screw.
5.7 Built-in remote control accessory
(optional)
Before you begin, read these instructions carefully. It is
recommended that the remote control be wired to the
hood after the hood is installed.
IMPORTANT: Cutting off a connector to the appliance or
to the extension cable kit will void the warranty.
REMCPW parts included:
Remote control (1)
¡
30 ft. extension harness (1)
¡
Installing the remote control
Prepare the cutout in the wall or similar surface for
1.
installation as shown below (view is shown facing wall).
Installation en-us