6. Commissioning, operation

6. Commissioning, operation
Required tool: Open-ended spanner (spanner width 27), screwdriver
CAUTION!
Prior to commissioning, the pressure transmitter must be subjected to a visual inspection.
Leaking fluid is indicative of damage.
Only use the pressure transmitter if it is in perfect condition with respect to safety.
Making the mechanical connection
For model A-10 with parallel thread, the sealing ring is included in the delivery.
During mounting, make sure that the sealing faces at the pressure transmitter
and the measuring point are clean and undamaged.
Only ever screw in, or unscrew, the instrument via the spanner-flats and to
the prescribed torque using an appropriate tool. The correct torque depends
on the dimensions of the pressure connection and the gasket used (form/
material). When screwing in or unscrewing the pressure transmitter, do not
use the housing for purchase.
When screwing in, do not cross the threads.
For information on tapped holes and welding sockets, see Technical Information IN 00.14 at
www.wika.com.
WIKA operating instructions pressure transmitter model A-10
GB
max. 50 Nm
17