5.1.2.1
"AUTO" MODE
At the end of the test, if the average
resistance value Ravg results to be
lower than 5Ω the instrument emits a
double sound signal indicating the
positive outcome of the test and
displays one screen similar to the
screen alongside.
SAVE
5.1.2.2
"R+" or "R-" MODE
At the end of the test if a resistance
value R+ or
R- lower than 5Ω was detected, the
instrument emits a double sound
signal
indicating
outcome of the test and displays
one screen similar to the screen
alongside.
Either the symbol R
the symbol R
SAVE
5.1.2.3
"R+TIMER" or "R-TIMER" MODE
At the end of the test if a resistance
value R+Timer or R–Timer lower
than 5Ω was detected, the instrument
(after the set time has elapsed) emits
a double sound signal indicating
the positive outcome of the test
displays one screen similar to the
screen alongside.
The symbols R+ or R- are displayed.
The test can be stored by pressing the SAVE key twice (see paragraph 0).
SAVE
The test can be stored pressing the SAVE key twice (according to
paragraph 0).
the
positive
+
or
-.
The test can be stored pressing the SAVE key twice (according to
paragraph 0).
CAL LOW
1.07
219
mA
AUTO
CAL LOW
1.07
219
mA
R+
R-
CAL LOW
1.08
219
5
mA
s
R+
R-
TIMER
11
Average
resistance
value Ravg.
Average test
current value
Iavg.
Resistance
value R+ or
R-.
Value
of
current I+ or I-.
Duration time of
the test.
Value
of
test current I+
or I-.
test
the