BD Veritor™ Plus Analyzer Instructions for Use
Analyzer Unpacking and Setup
1
Before using the BD Veritor Plus Analyzer, visually inspect the contents for damage. If damage is apparent, contact your
BD Representative or BD Technical Services.
2
The BD Veritor Plus Analyzer ships with an adhesive-backed USB Port Unlock Barcode label, which is used on Analyzers that are
configured with a BD Veritor InfoScan Module or BD Veritor InfoSync Module. BD recommends affixing this label to the space
indicated on the cover page of this manual or kept in a secure location of your choice for future use. Instructions for using the USB
Unlock Barcode can be found in section 4.6. These optional modules may not be available in all regions; please contact your local BD
representative for availability.
3
Remove the Analyzer and power adapter from the protective wrapping. BD recommends retaining the packing materials in a safe
location.
4
Refer to the figure below. Select the blade adapter that is appropriate for the local region. Blades included are:
• North America / Japan NEMA 1-15P
• United Kingdom BS 1363
• European CEE 7/16
5
Slide the retaining clip (1) down on the power adapter.
6
Insert the notched end (2) of the blade adapter into the top of the power adapter at a 30–60 degree angle.
7
Push the bottom (3) of the blade adapter into the power adapter.
8
Slide the retaining clip (1) up to lock the blade adapter in place.
9
Insert the coaxial power connector into the round port on the back of the Analyzer, and insert the power adapter plug into an electrical
outlet.
10
Perform a verification test as described in section 5.1.1, BD Veritor System Verification Cartridge.
2.4
Printer Setup
Optional
–
Printer Unpacking and Setup
The BD Veritor Plus Analyzer can be configured to print test results to a connected printer. The printed language will match the currently
configured display language. The BD Veritor Plus Analyzer supports only specific printer models. Contact your BD representative to obtain
a list of compatible printer models and operating instructions. A USB 2.0 On-The-Go micro-A to B cable, or USB On-The-Go adapter, is
required. The cable may be purchased from computer supply retailers or may be ordered from BD under catalog number 443907.
For unpacking and setup instructions, or information about ordering replacement paper, refer to the instructions provided with the printer.
The printer is connected to the BD Veritor Plus Analyzer as follows:
1
Connect the USB B end of the USB cable to the corresponding port on the back of the printer.
2
Connect the USB micro-A end of the USB cable to the corresponding rectangular port on the back of the BD Veritor Plus Analyzer.
6