3. 6 Adjusting air when lighting a fire
Primary air inlet
-
It is essential to open this inlet to maximum position when lighting the fire and to leave the door half-closed
to avoid the condensation of fumes on the glass.
You must wait enough time (until the appliance has warmed up) before adjusting the air inlet.
Secondary air inlet
-
Open fully when lighting a fire.
3. 7 Adjusting air during operation
- Primary air inlet
During normal operation of the burner, once the appliance has warmed up, you must close the primary air inlet to
achieve good combustion performance.
If the quality of the firewood allows it, the primary air inlet must be fully closed or slightly open (no more than 1 cm).
PRIMARY AIR REGULATION LEVER POSITION FOR NOMINAL POWER, LEAVE (open 5mm.).
- Secondary air inlet
Secondary air adjustment is the one that will provide better combustion that is cleaner and more efficient, making the
most of every load of firewood.
You can adjust the entry of secondary air when the apparatus is hot enough and burning with a good flame.
During normal operation, you must never close the secondary air inlet completely. Normally, the secondary air must
be adjusted to a minimum opening of 15-20%.
SECONDARY AIR REGULATION LEVER POSITION FOR NOMINAL POWER, OPEN 30% OF ITS RANGE.