Encimera inducción trifásica

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

MODELS
DIMENSIONS cm
POWER SUPPLY
MAXIMUM ABSORPTION A
MAXIMUM POWER kW
POWER SUPPLY CABLE
MINIMUM VENTILATION IN
MINIMUM VENTILATION OUT
MAX AMBIENT TEMPERATURE
COMPARTMENT GENERATOR
The data plate is on the front (see diagram in electric connection item) and has all the data necessary for the connection.
When fitting, the appliance must be leveled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishes, etc., these should be in flameproof material; otherwise
it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that fire prevention standards are observed.
Always comply with the following points during installation:
-
Ensure that mains voltage complies with the voltage indicated on the specification table of the
appliance
-
All electrical installations must comply with local standards. All standards issued by national electrical authorities
must be complied with.
-
When circuit breakers are used, they must be suitable for a minimum of 30 mA.
-
Avoid obstruction of air intakes or outlets with objects (fabric, walls, etc).
GB
GENERAL TECHNICAL DATA
Minimal pan diameter:
Relative humidity:
Operation Ambient temperature:
Voltage tolerance:
Supply frequency:
TECHNICAL DATA TABLE
PCID-64ET... PCID-68ET... PCIWD-64ET... PCID-84ET... PCID-44ET... PCID-44ET...
40x60x31h
80x60x31h
400V~3 50/60Hz 400V~3 50/60Hz 400V~3 50/60Hz 400V~3 50/60Hz 400V~3 50/60Hz 400V~3 50/60Hz
14,4 A
29 A
10 kW
20 kW
4x1,5 mm²
4x4mm²
100 cm²
165 cm²
150 cm²
200 cm²
35°C
35°C
INSTRUCTIONS FOR INSTALLATION
INSTALLATION
IE
120 mm
10% to 90% non-condensing
0°C ÷ 40°C
-10% ÷ +6%
50 – 60 Hz
40x60x31h
40x80x31h
7,2 A
14,4 A
5 kW
10 kW
4x1,5 mm²
4x1,5 mm²
50 cm²
100 cm²
82 cm²
150 cm²
35°C
35°C
46
40x40x31h
40x40x31h
7,2 A
7,2 A
5 kW
5 kW
4x1,5 mm²
4x1,5 mm²
50 cm²
50 cm²
82 cm²
82 cm²
35°C
35°C