Descargar Imprimir esta página

Lotus PCID-64ETX Guia Para La Intalación E Instrucciones De Uso página 54

Encimera inducción trifásica

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

· CAUTION: NEVER carry out any work on the induction generators without first having disconnected them from the
power supply .
· HAZARD: high voltage present in induction generators powered by the electricity supply .
· The induction generators should only be opened by QUALIFIED, AUTHORISED PERSONNEL IN COMPLIANCE
WITH INTERNATIONAL, NATIONAL AND REGIONAL
SAFETY LAWS AND REGULATIONS.
Fault
Insufficient heating of cooking
zone
Continuous heating of cooking
zone at maximum power
Empty cooking zone starts
operating
Small metal objects are heated
No heating of cooking zone
No reaction of appliance
Fuses blow when switching on
There are two different error types:
Generator errors (E1)
Digital control errors(E2)
Generator errors are faults detected by the generator and forwarded to the control. On the display of the
digital control "E1" appears. On the analogue controls faults can be detected according to the duration and
frequency of the green light blinking. The green lamp lights one time long and than short regular flashes.
The number of these short flashes is the error number. This pattern is constantly repeated.
For example: error code E1 06 from the generator:
long
1
The red fault lamp remains on as long as an error exists.
Digital control errors are faults from the digital controls. On the display appears "E2" and than the error number
GB
TROUBLESHOOTING.
Cause
Unsuitable pan material
Knob switch faulty
Pan detection sensor faulty
Pan detection sensor faulty
Pan bottom Ø less than 12 cm
Generator defective
Mains fuse / main supply
interrupted
Short-circuit in generator
ERROR CODE PATTERN
2
3
4
5
6
IE
Corrective action
Use suitable pan material
Check / replace knob switch
Replace generator / have it repaired
Replace generator / have it repaired
Use suitable pan material
Replace generator / have it repaired
Check mains connection
Replace generator / have it repaired
long
1
2
3
4
53
5
6

Publicidad

loading