FAULT MESSAGES FROM THE GENERATOR (E1)
Error.
No.
Name
E1
01
Hardware over current
No inductor current
E1
02
IGBT temperature too
E1
03
high
Cooking zone
E1
04
temperature too high or
too low
E1
05
Control unit failure
Internal temperature
E1
06
too high
E1
07
Coil temperature
Mains phase failure
E1
08
E1
10
Communication error
E1
11
Initialisation error
Mains connection
E1
error
13
Mains adaptor error
E1
14
E1
15
Empty pan protection
GB
IE
Cause
Unsuitable pan material
Wrong or defective coil
Inductor connection failure
Air routes blocked
Fan clogged, temperature
sensor of IGBT defective
Pan empty
Temperature sensor faulty
Power board faulty
Control unit defective or
wiring defective
Digital control has faulty ID
Control unit faulty
Air routes blocked
Fan clogged, temperature
sensor defect, close exterior
heat sources
Coil temperature to high
Temperature sensor faulty
Breakdown of mains phase or
mains quality insufficient
Failure on LIN or CAN-Bus,
no connection between
keyboard and generator
Needless control unit
connected
Digital control has faulty ID
Failure while initialising of the
hardware
Mains voltage is too high or
too low
Mains voltage is too high or
too low
Mains error
Empty pan
Defective temperature sensor of
the coil
54
Corrective action
Use suitable pan material
Check the coil
Connect the inductor properly
Clear air routes
Clean fan, check fan rotation
Remove pan, switch off and wait a
couple of minutes until the cooking
field has cooled down
The sensor must be replaced
Replace the generator
Check or replace operating unit,
check wiring harness to unit
Switch the generator off, adjust the
DIP-switches correctly
Replace the control unit
Clear air routes
Clean fan
Remove pan, switch off and wait a
couple of minutes until the cooking
field has cooled down
The sensor must be replaced
Check mains supply
Disconnect from mains and check
connection
Connect control unit to the correct
control plug
Switch the generator off, adjust the
DIP-switches correctly
Just wait, the device will be reset
approx. every 30 sec.
Check mains connection
Check mains connection
Switch off the main fuse, wait a
few seconds and switch on
Remove pan, switch off and wait
for a couple of minutes until the
cooking field has cooled down
The sensor must be replaced