Proper use

The charger is designed to charge the batteries listed below. Any use above and beyond
this purpose is deemed improper. The manufacturer shall not be liable for any damage re-
sulting from such improper use. Proper use also includes:
-
-
The following batteries may be charged:
-
-

Mains connection

The rating plate, which is located on the housing, contains information about the permitted
mains voltage. The charger is designed for this mains voltage only. The fuse protection re-
quired for the mains lead can be found in the "Technical data" section. If there is no mains
lead or mains plug on your device, fit one that conforms to national standards.
52
WARNING! Incorrect operation may result in serious injury or damage. Do not
use the functions described here until you have thoroughly read and understood
the following documents:
-
Operating instructions
-
All the operating instructions for the system components, especially the safe-
ty rules
-
Battery and vehicle manufacturers' operating instructions and safety rules
Complying with all the instructions in the operating instructions
regular checking of the mains and charging leads
WARNING! Charging dry batteries (primary cells) and non-rechargeable batter-
ies can cause serious injury or damage, and is therefore prohibited.
WARNING! Risk of serious injury and damage from charging non-permitted lithi-
um batteries or incorrect charging settings. Only 12 V lithium batteries may be
charged, and these must only be charged with the correct charging settings, as
per the "Permitted lithium batteries" section of the "Technical data" chapter.
Lead batteries (exclusively Wet and AGM) with the following settings:
Pb Charge
, Backup Mode
, Pb Refresh
, Pb Initial Charging
Lithium batteries with the following settings:
Li-Ion Charge
, Backup Mode
Only preselected 12 V lithium batteries may be charged as per the "Permitted lithium
batteries" section of the "Technical data" chapter.
NOTE! Inadequately dimensioned electrical installations can cause serious dam-
age. The mains lead and its fuse must be dimensioned to suit the local power sup-
ply. The technical data shown on the rating plate applies.