Pb Charge Mode; General Information; Pb Charge - Fronius XCharge_professional Manual De Instrucciones

Sistema de carga de baterías
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Pb Charge mode

General informa-
Pb Charge mode is used for:
tion
-
-

Pb Charge

1
5
The charger automatically recognises the connected battery and starts the charging pro-
cess after approximately 5 seconds.
If the device remains in standby when the battery is connected, then the battery is in a state
of extreme deep discharge (< 2 V).
12 V lead batteries
Charging or conservation charging with the battery either fitted or removed
WARNING! Risk of serious injury and damage from incorrect charging settings or
a defective battery. Before beginning the charging process, ensure that the set-
tings on the charger for the battery to be charged are correct and that the battery
is functioning properly.
Plug in charger mains plug
Select Pb Charge mode using the up/down keys.
2
Select the Ah range for the battery to be charged using the
3
Menu key.
Specify the appropriate Ah value using the up /down keys.
4
Connect the battery, observing the correct polarity. Because the charging terminals
are de-energised, there is no risk of sparks when connecting to the battery, even if the
charger is already connected to the mains supply.
-
Connect the red charging lead to the positive pole (+) of the battery
-
Connect the black charging lead to the negative pole (-) of the battery
61

Publicidad

Tabla de contenido
loading

Tabla de contenido