Charging Errors - Fronius XCharge_professional Manual De Instrucciones

Sistema de carga de baterías
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Charging errors

No. 33: Optional external temperature sensor has tripped due to overtemperature
Remedy:
-
No. 35: Voltage below target voltage after 2 h - Pb Refresh mode in analysis phase
Remedy:
-
-
No. 36: Cell short circuit
Remedy:
-
-
Allow battery to cool or charge it in an area with a more suitable temperature
Check for parallel consumers (GPS etc.)
Replace battery if it is faulty
Check for parallel consumers (GPS etc.)
Replace battery if it is faulty
Battery undervoltage
Remedy:
-
Set the correct operating mode and
voltage
No. 30: Timeout in the corresponding char-
ging phase
Remedy:
-
Set Ah to correct value
-
Check for parallel consumers (GPS
etc.)
-
Battery temperature too high
No. 31: Too many Ah charged, too few Ah
set
Remedy:
-
Set Ah to correct value
-
Check for parallel consumers (GPS
etc.)
-
Replace battery if it is faulty
No. 32: Optional external temperature sen-
sor has tripped due to undertemperature
Remedy:
-
Charge the battery in an area with a
more suitable temperature
75

Publicidad

Tabla de contenido
loading