Arc-force setting indicator
8-
Variable inductance setting indicator
9-
Indicators
10- Secondary setting knob
11- Locked keypad indicator
12- Locked keypad button
POWER SUPPLY – STARTING UP
• This machine is fitted with a 32A socket type EN 60309-1 which must only be used on a three-phase 400 V (50-60 Hz) four-wire earthed electrical
installation.
The absorbed effective current (I1eff) is indicated on the device for optimum operating conditions. Check that the power supply and its safeguards
(fuse and/or circuit breaker) are compatible with the electric current being used. In some countries, it may be necessary to change the plug to allow
the use at maximum settings.
• The device is designed to operate on an electrical voltage of 208 to 525V +/-15%. The unit enters protection mode if the supply voltage is less than
185Vrms or greater than 600Vrms (a fault code will appear on the display).
• The start is done via an on / off switch (6) set to I, and the stop is done by switiching it to O. Attention ! Never disconnect the power supply
when the machine is on.
CHANGEMENT DU CABLE D'ALIMENTATION
U
1
208-380 V
380-525 V
1~50/60 Hz
208-380 V
380-525 V
3~50/60 Hz
CONNECTION ON A GENERATOR
The machine can work with generators as long as the auxiliary power matches these requirements :
- The voltage must be alternating, with an RMS value of between 208 and 525V +/- 15%, and a peak voltage of less than 900V,
- The frequency must be between 50 and 60 Hz.
It is imperative to check these requirements as several generators generate high voltage peaks that can damage these machines.
USE WITH EXTENSION CABLES
All extension cables must have an adequate size and section, relative to the machine's voltage .
Use an extension that complies with national safety regulations.
Input voltage
208-380 V
380-525 V
ELECTRODE WELDING (MMA
CONNECTIONS AND RECOMMENDATIONS
• Connect the cables, electrode holder and earth clamp in the connectors,
• Respect the welding polarities and intensities indicated on the electrodes boxes,
• Remove the electrode from the electrode holder when the machine is not in use.
VRD
V
The grey areas are not useful for this mode.
18
EXAGON 400 FLEX CC/CV
Minimum
L'appareil est livré d'origine avec un cable secteur 4 x 4 mm
recommanded section
Ce cable secteur est dimensionné pour fonctionner sur une tension d'alimentation triphasée com-
prise en 380 V et 525 V.
10 mm² (or AWG 8)
4 mm ² (or AWG 11)
Sur une tension d'alimentation monophasée ou triphasée comprise en 208 V et 380 V, le cable sec-
10 mm² (or AWG 8)
teur doit être changé. Le fabricant recommande un cable avec une section de 10 mm
Une plaque et un presse-étoupe sont livrés avec l'appareil pour faire cette modification.
4 mm ² (or AWG 11)
Cross-section of the extension cable (Length < 45m)
10 mm²
4 mm²
AND MMA VERTICAL UP
MMA
MIG
A
press 3 s
Basic
7018
CV
0
Rutile
6013
Cellulosic
6010
ARC FORCE
INDUCTANCE
press 3s
setup
-9
+9
memory
MMA
19-
MMA pulse mode indicator
20-
Voltage mode indicator (CV)
21-
TIG mode indicator
22-
Gouging mode indicator
23-
Selection mode button
)
TIG
Gouging
MODE
press 3s
et une prise 32 A de type EN 60309-1.
2
VRD
V
A
press 3 s
Basic
7018
0
Rutile
6013
Cellulosic
6010
ARC FORCE
INDUCTANCE
-9
+9
MMA Vertical up
The grey areas are not useful for this mode.
EN
par phase.