Descargar Imprimir esta página

GYS EXAGON 400 FLEX CC/CV Manual Del Usuario página 21

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
MODE SELECTION AND SETTINGS
Press the button
several times until the LED light switches on below the
symbol
.
Adjust the welding current using the main knob according to the electrode dia-
meter
, the current set point is shown on the right-hand display.
DISPLAY CURRENT/VOLTAGE DURING WELDING
During welding, the machine measures and displays the welding current and voltage. After the weld, the average current and voltage values are
displayed during 30 seconds, as soon as a knob or a button is pressed, the welding parameters are displayed.
SAVE AND LOAD WELDING SETTINGS
The current settings are automatically saved and loaded at start up.
On top of the current settings, it is also possible to save and load 50 settings per each mode.
The memory recalls :
- Primary setting
- Secondary setting (MMA, CV)
- Secondary settings (MMA)
Save new settings :
- Maintain buttons
and
- Turn one of the two knobs
- The display indicates a memory set (01 to 50) while blinking.
- Turn the knob to select the memory set in which the desired settings will be saved. Validate by pressing the button
- The settings are saved / the menu exit is instantaneous.
Load existing settings :
- Maintain the buttons
and
- Turn one of the two knobs to display
- The display indicates a memory set (01 to 50) while blinking.
- Turn one of the two knobs to select the memory set containing the desired settings to load. Validate by pressing the button
The settings are loaded / the menu exit is instantaneous.
REMOTE CONTROL
The remote control option or pedal option has not been designed to operate on the EXAGON when the EXATIG (ref. 013780) is
connected. The current can be adjusted by using the potentiometer torch (ref. 047877) connected to the EXATIG which controls
the EXAGON's current level.
CONNECTIONS AND RECOMMENDATIONS
The remote control works in all modes.
The remote control acts on the primary settings of the current process (MMA and TIG, voltage and gouging).
Connections :
1- Plug the remote control on the machine's front.
2- The machine will detect the remote control automatically and open a selection menu:
Foot pedal selection.
Remote control with potentiometer selection.
The remote ontrol type selection is done with the two knobs, the validation is done with the button
The LED (FIG-2, n°14) switches on.
It is possible to activate / deactivate the remote control without having to physically unplug the remote control. Press the button
seconds, the LED (FIG-2, n°14) indicates the state of the remote control (LED on = remote control on).
EXAGON 400 FLEX CC/CV
during 3 seconds.
. Validate by pressing the button
during 3 seconds.
. Validate by pressing the button
VRD
V
The grey areas are not useful for this mode.
appears, release the buttons.
.
appears, release the buttons.
.
MMA
MIG
A
press 3 s
Basic
7018
0
Rutile
6013
Cellulosic
6010
ARC FORCE
INDUCTANCE
press 3s
-9
+9
memory
.
.
.
, for 3
EN
TIG
Gouging
CV
MODE
press 3s
setup
21

Publicidad

loading

Este manual también es adecuado para:

069718