Applications; Delivery Contents - Aventics RMV04-8DI M8 Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 155
46
AVENTICS | EtherNet/IP™ | R412012728–BDL–001–AC

Applications

On installation
During commissioning
During operation
During cleaning
A 24 V power pack supplies all components with electricity. The power pack must be
fitted with a safe isolation in accordance with EN 60742, VDE 0551 classification.
This ensures that the electric circuits comply with SELV/PELV electric circuits in
accordance with IEC 60364-4-41.
Switch off the operating voltage before connecting or disconnecting plugs.
The warranty only applies to the delivered configuration. The warranty will not apply
if the product is incorrectly assembled.
Make sure the relevant system component is not under pressure or voltage before
assembly or disassembly. Ensure that the system is prevented from power
restoration during assembly work.
Ground the modules and valve system. Observe the following standards when
installing the system:
– DIN EN 50178, classification VDE 0160
– VDE 0100
Installation may only be performed in a voltage-free and pressure-free state and
only by a qualified technician. In order to avoid accidents caused by dangerous
movements of the actuators, electrical commissioning is to be carried out only in
a pressure-free state.
Do not put the system into operation before it is completely assembled as well
as correctly wired and configured, and after it has been properly tested.
The device is subject to the restrictions in the IP 65 protection class. Before
commissioning, make sure that all the connection seals and plugs are leaktight
to prevent fluids and foreign bodies from penetrating the device.
Make sure that there is a sufficient exchange of air or enough cooling if your valve
system has any of the following:
– Full equipment status
– Continuously loaded solenoid valves
Never use aggressive solvents or detergents. Only clean the device using
a slightly damp cloth. Only use water and, if necessary, a mild detergent.
3
Applications
The bus coupler is used to electrically control valves via the EtherNet/IP™ field bus
system. In addition, input/output modules allow electrical input and output signals to
be connected via the valve system's bus connection.
The bus coupler is only intended for use as a slave in an EtherNet/IP™ bus system in
accordance with EN 50170 Part 2.
4

Delivery contents

The following is included in the delivery contents of a configured valve system:
1 valve system according to configuration and order
1 set of operating instructions for the valve system
1 set of operating instructions for the bus coupler
The following is included in the delivery contents of a bus coupler parts kit:
1 bus coupler with seal and two tie rods
1 set of operating instructions
The VS is individually configured. You can find the exact configuration in the
AVENTICS Internet configurator under your order number.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rmv04-8di m12

Tabla de contenido