Instructions for the installation engineer
Installation and connection must
be done in compliance with the
regulations in force. All repairs
may only be carried out once the
appliance is turned off. Repairs
must only be carried out by
qualified service engineers.
The
manufacturer
liability in cases where safety
regulations
followed.
Connecting to the electrical supply
Please take note of the following
requirements before connecting:
- The fuse or other protective device
and the domestic electrical instal-
lation must be designed for the
max. load of the appliance (see
rating plate).
- The domestic electrical installa-
tion must be equipped with a
proper
accordance with the regulations in
force.
- The socket or multi-pole off switch
must be easily accessible, even
after completed installation of the
appliance.
This appliance is supplied with a con-
nection cable incorporating a standard
plug, suitable for the total electric load
shown on the rating plate. The plug is to
be inserted into a suitable wall socket.
The following types of connection cable are
suitable, considering the required rated
cross-section for the given situation: H07 RN-
F, H05 RN-F, H05 RR-F, H05 VV-F, H05 V2V2-
F (T90), H05 BB-F.
With a direct connection between the oven
and the electricity supply or if the socket is
inaccessible, an all-pole circuit breaker with
a minimal contact port of 3mm must be
built in. The switch must not interrupt the
protective conductor at any point. The earth
wire must be 2-3 cm longer than the phase-
to-neutral conductor.
denies
have
not
earth
connection
The connection cable must in any case be
laid out so that at no point does it reach
50°C (over room temperature).
Once successfully connected, check the heat-
ing elements after approx. 3 minutes of use.
all
Terminal block
been
The oven is equipped with an easily
accessible terminal block, which is meant
for operation with a single phase voltage
of 230 V.
L
-
N
-
or E -
in
Live terminal
Neutral terminal
Earth terminal
progress 21