MOUNTING THE BUILT-IN COOKTOP
Caution !
• To avoid any possible hazard, the appliance may be installed by qualifi ed personnel only.
• Panels and furniture lining of the kitchen cabinet receiving the hob must be treated with temperature resistant adhesives
100°C (otherwise they might be discoloured or deformed because of inadequate temperature resistance).
• The cooking hob is intended for building into the worktop above the kitchen element of 600 mm width or more.
• After the installation of built-in hob make sure that there is free access to the two fixing elements in front.
• Suspended kitchen elements above the cooktop must be installed at such distance to provide enough room for
comfortable working process.
• The distance between the worktop and the hood must be at least such as indicated in the instructions for installation of
the kitchen hood, but in no case it may be less than 700 mm.
• The use of hard wood decorative borders around the worktop behind the appliance is allowed, in case the minimum
distance remains as indicated on the installation illustrations.
• Minimum distance between the built-in cooktop and rear wall is indicated at the illustration for the installation of the built-
in cooktop.
Built-in induction hob
opening dimensions
FHBP 604 4I PW T
XS
A
600mm
B
510mm
C
560mm
D
490mm
E
50mm
F
10mm
G
50mm
H
5mm
FHBP 803 3I T
FHFB 302 2I
XS
810mm
320mm
380mm
510mm
790mm
307mm
360mm
497mm
50mm
50mm
10mm
10mm
50mm
50mm
5mm
5mm
FHBP 603 3I
T
T XS
580mm
510mm
560mm
490mm
50mm
10mm
50mm
5mm