Installation diagram
TECNICAL INFORMATION
Type
Width
Rated voltage
Type of switch
Cooking zones (Ø, mm/W)
Forward left
Rear left
Central
Rear right
Forward right
Total power (W)
Type
Width
Rated voltage
Type of switch
Cooking zones (Ø, mm/W)
Forward left
Rear left
Central
Rear right
Forward right
Total power (W)
P= EXTRA POWERFUL SETTING
ATTENTION !
Before attempting any repairs on the appliance, disconnect the power supply. In
accordance with the mains voltage the appliance should be connected in line
with the attached diagram.
The earthing wire (PE) must be connected to the terminal marked with the
earthing symbol.
The connection cable must lead through the relief safety device, protecting it
from accidental pulling out. Upon the completion of installation switch all the
hotplates on for about 3 minutes to check the proper functioning.
Connection may be carried out by means of:
- rubber coated connection cables, model H05RR-F with yellow-green
earthing cable;
- rubber coated connection cables, model H07RN-F with yellow-green
earthing cable.
FHBP 604 4I PW T XS - FHBP 803 3I T XS - FHBP 603 3I T XS
FHBP 604 4I PW T XS
600x510
220-240 V~ or 380-415 V 2N~, 50/60 Hz
160 / 1,4
200 / 2.3 (P=3.0)
-
200 / 2.3 (P=3.0)
160 / 1.4
7.4
FHFB 302 2I T
320x510
220-240V~ o 380-415V 2N~, 50/60 Hz
160 / 1.4
-
-
-
200 / 2.3 (P=3.0)
3.7
FHFB 302 2I T
FHBP 803 3I T XS
Electronic sensors
210 / 2.3 (P=3.0)
270 / 2.3 (P=3.0)
FHBP 603 3I T XS
Electronic sensors
200 / 2.3 (P=3.0)
270 / 2.3 (P=3.0)
810x380
160 / 1.4
-
-
6.7
580x510
160 / 1.4
-
-
6.7
23