FLEX 3000 DUO CONTROL PANEL
The control panel is separated in two main sections: section 1 and section 2:
Section 1:
Setting through
key pads,
control knobs
.
and display
Section 2:
Setting though
defined key
.
pads
Section 1 (Upper part of the panel)
Display
-
: Indicates value and unit for either
• Welding current in amp
• Wire feed speed in m/min
• Material thickness in mm
-
: Indicates value and unit for either
• Trim of welding voltage
• Welding voltage in volt
• Arc adjust (electronic choke)
• Gas flow (special equipement)
:
Indicates the selected welding
program
:
Indicates
fault
symbols. Description can be seen on
page 23 - 24.
:
Indicates sequence and tack function
and
information
Key pads
FLEX 3000 has the following key pads in section 1:
Changes between the following in the left
side of the display:
-
-
-
Changes between the following in the right
side of the display:
-
-
-
-
Is used for selection of program. The key
pad in function can be seen on page 22.
Is used for setting of sequences:
Description of sequences can be seen on
page 22.
18
M/min
Materialthickness in mm
Current strength in amp
Voltage
Voltage trim
Arc adjust (-5,0 - +5,0)
Gas flow (5-27 l/min)
(special equipment)