Data Sheet, L 400 Sender/Receiver; Tab.11: Technical Data, L 400 Sender/Receiver - SICK L 4000 Manual De Instrucciones

Ocultar thumbs Ver también para L 4000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 118
Chapter 9
Tab.11: Technical data,
L 400 sender/receiver
322
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Technical data
9.2

Data sheet, L 400 sender/receiver

Supply voltage
Power consumption
Electrical protection class
Safety category
Wavelength
Aperture angle/
receiving angle
Diameter (optics)
Distance sender-
receiver
Ambient operating
temperature
Humidity (non-
condensing)
Storage temperature
Housing material
Optics
Enclosure rating
Response time
Input signal (sender only)
Output signal (receiver
only)
Shock resistance
Rigidity
Weight (plastic/metal)
11)
For continuous sending (that is alignment, PIN 4 of the sender not connected)
minimum
typical
19.2 V DC
24 V DC
III
Type 4 in compliance with IEC 61 496
(only in conjunction with safety evalua-
tion device UE 401)
660 nm (red)
12 mm
0 m
–20 ° C
15 %
–25 ° C
Plastic or nickel plated brass
Plastic
IP 67
LOW —>
HIGH: 0.4 ms
HIGH —>
LOW: 0.6 ms
HIGH: Transmission inactive
LOW or open circuit: Transmission active
HIGH: Light beam interrupted
LOW: Light beam unobstructed
10 g 16 ms acc. to IEC 60068-2-29
5 g, 10 Hz ... 55 Hz acc.
to IEC 60068-2-6
30/67 g
Operating Instructions
L 4000 system
maximum
28.8 V DC
11)
60 mA
(Sender)
30 mA
(Receiver)
±2.5°
axial 10 m
radial 5 m
+55 ° C
95 %
+75 ° C
8010009/TI69/2009-11-26

Publicidad

Tabla de contenido
loading

Tabla de contenido