In the event of use of Ø 202 mm holes, work as follows:
Use pincers to break the precut of the rear cover (fig. 21-A).
a.
b.
Then, rotate back and forth the part of the cover to be remove with the hand until
breaking the remaining precut part (fig. 21-B).
c.
Use a cutter to trim the possible insulating material in excess which remained
inside the hole (fig. 21-B).
21
2.4.5 - Positioning of the device on the anchor brackets
Working on the two previously drilled holes
(see fig. 6), fix the support bracket (L) to the
wall using the supplied wall plugs screws
(H) (fig. 22).
After checking:
that the fixing brackets are well an-
chored to the wall,
that the installation site has been
prepared for electrical connection and
condensation discharge (if necessary),
it is possible to hook the air
conditioner.
Lift the air conditioner by
holding it on the sides of the
lower base and hook it to the
bracket (L) (fig. 23).
Slightly tilt the lower part of the
appliance towards yourself to
ease the operation.
EN - 20
A
22
23
L
B
L
E
E

Publicidad