Do not perform them alone.
4.2.1 - Routine maintenance
The air conditioner that you have purchased has been designed to reduce routine
maintenance operations to a minimum.
These operations involve solely the cleaning operations outlined below:
• Cleaning or washing of the ambient air filter every 2 weeks or every time the
relative red LED lights up (this can be done by the user, see user manual).
• Cleaning of the condensing battery and cleaning of the condensate management
system.
These operations must be carried out by skilled technicians on a regular basis that
will depend on the place of installation and intensity of use.
Depending on the quantity of dirt, the unit can be cleaned dry (by using a battery
compressor and bowl and cleaning the fins with a soft brush taking care not to deform
them) or more thoroughly using dedicated detergents.
4.2.2 - Condensation water drainage in case of emergency
If anomalies occur in the condensa-
tion water disposal system, the air
conditioner stops and signals the
alarm status with the intermittent
lighting up of LED A, LED B and
LED C (fig.29).
To enable the air conditioner to
work temporarily until the service
personnel arrive, you can drain the
water out by following these simple
instructions (fig. 38):
Remove the bottom cover.
a.
Remove the cap (6a) after
having placed a good-sized
container underneath it (at least
5-liter capacity) to collect the
water.
29
6a
min. 5L
38