Descargar Imprimir esta página

CESVA LRS-03 Manual Del Usuario página 30

Limitador registrador sonométrico

Publicidad

Idiomas disponibles

Idiomas disponibles

PROGRAMMING: This allows you to consult all the programmed parameters in the LRS-
-
03. These parameters are the following:
Session timetable: This allows you to consult the working timetable of the
establishment that has been programmed for each day of the week.
NOTE: Outside the session timetable, the LRS-03 attenuates 60 dB.
Regulation: With this option, the information related to the regulation that the
establishment must observe can be consulted.
Operation mode: This displays the operation mode: equivalent continuous level of 1
second (Leq1s) or "fast" level (LF )
Attenuation time: This allows you to consult the duration of the attenuation of 60 dB.
Non working periods: This option displays the non-working periods.
Leq time: This displays the duration of the equivalent continuous sound pressure level
measurement.
Continuous printing: This allows you to consult if the date and time of the beginning
and end of the interval and the equivalent continuous level and the maximum "slow"
level measured in this interval will be printed at the end of each LeqT measurement. If
there is no printer connected, the LRS-03 will record an error.
LS max Limit: This displays the maximum allowed value of "slow" level.
LF max Limit: This displays the maximum allowed value of "fast" level.
Modem Parameters: This allows you to select the number of rings that the LRS-03
waits before it attends a request received by modem.
-
LeqT RECORDS: This option allows you to consult all the LeqT records stored in the
LRS-03. For greater convenience, first introduce the date and the time from which you
want to consult the records database. The LeqT records contain the following
information. The records contain the following information:
 Date and time of the beginning of the leqT interval
 Date and time of the end of the leqT interval
 Equivalent continuous level measured in the interval
 Maximum allowed equivalent continuous level depending on the evaluation
timetable (day or night)
 Level, date and time of the maximum 1 minute Leq measurement obtained in the
interval
 Level, date and time of the minimum 1 minute Leq measurement obtained in the
interval
 Time in seconds that the LRS-03 has been disconnected form the main supply
during the interval (Disconnection).
 Time expressed in seconds that the LRS-03 has attenuated 60 dB and the sound
pressure level has continued exceeding the programmed limit in the interval (Limit
exceeded)
 Time in seconds that the sensor has been manipulated during the interval (Sensor
inact.).
 Record that indicates if a printer error has occurred in the LeqT interval (Printer
error). Usually, this error is due to the fact that the printer is not connected at the
time of printing. This error will only be registered if the option continuous printing
from the programming menu has been selected.
28

Publicidad

loading