Descargar Imprimir esta página

CESVA LRS-03 Manual Del Usuario página 32

Limitador registrador sonométrico

Publicidad

Idiomas disponibles

Idiomas disponibles

13/09/99
14/09/99
22:30 < --> 03:00
Leq :
83.2 dBA
Day limit
: 90dBA
MaxLeq1':
86.1 dBA
14/09/99
02:55
MinLeq1':
UND dBA
13/09/99
23:51
-
BATTERY END DATES: Before the battery runs flat, the LRS-03 registers the date and
time when it happens. The last 10 times this happened can be consulted by selecting this
option in the display menu.
-
PROGRAMMING DATES: With this option the last ten times the LRS-03 was
programmed can be consulted.
DATA DELETED DATES: This allows you to consult the last ten times that the data
-
stored in the LRS-03 were deleted.
TOTAL COUNTERS: This allows you to consult the total counters. These counters are
-
the following ones: Limit exceeded (in seconds), sensor inactive (in seconds) and total
number of data deletions.
-
VERSION and SERIAL NO: This shows the serial number and the version number of the
LRS-03.
Night timetable:
22:00 < -->
Night limit :
85 dBA
Attenuat. time:
LS max :
84.2 dBA
Exceed.: 0
>90 dBA
LF max :
87.0 dBA
Exceed.: 1235 >90 dBA
30
Disconnection:
08:00
Limit ex cede :
Sensor inac.:
2 s
Percentiles (dBA)
L1
: 86.3
L5
: 84.2
L10 : 81.5
0
0
0
L50: 81.1
L90: UND