Connected voltage
Connection version
Power consumption P
1
Nominal current
Mains frequency
Protection class
Speed
Operating mode
Max. switching frequency
Max. total delivery head
Max. permitted geodesic delivery
head
Max. permissible pressure in
the pressure pipe
Max. volume flow
Max. fluid temperature
Min. fluid temperature
Max. ambient temperature
Max. solid grain size
Sound pressure level
(depending on duty point)
Gross volume
Max. switching volume
Max. inflow in one hour
Switch-on level, pump 1
(to the installation level)
Dimensions (W/D/H)
Diagonal dimension
Net weight
Pressure connection
Inlet ports
Ventilation
1)
*
Improper system and pipe installation, as well as impermissible operation, can increase the acoustic emissions.
Faeces lifting unit for buildings, DN 80
Lifting power
Noise level
Corrosion protection – coated, or corrosion-resistant
Installation and operating instructions Liftson L
5.2 Technical data
Liftson L-V-208/...
2,95T4
3,8T4
[V]
3~400 ± 10 %
Switchgear with with main switch
[kW]
3.0
3.8
[A]
6.0
6.9
[Hz]
50
System: IP 67 (2 mWS, 7 days)
Switchgear: 54
[rpm]
See name plate
S3-15 %/120 sec
[1/h]
30
[mWS]
10
15
[mWS]
9
13
[bar]
3
[m³/h]
See name plate
[°C]
40 (briefly 3 min, 60°C)
[°C]
3
[°C]
40
[mm]
40
1)
[dB(A)]
< 70 *
[l]
115
[l]
35
[l]
1050
[mm]
175
[mm]
630/770/630
[mm]
945
[kg]
55
[DN]
80
[DN]
50, 100, 150
[DN]
70
CE
09
EN 12050-1
- See pump curve
- < 70 db(A)
materials Inox/composite
Please state all the information on the system name plate when ordering spare parts.
Liftson L-2V-208/...
4,9T4
5,3T4
2,95T4
3~400 ± 10 %
4.9
5.3
2 x 3.0
8.5
8.9
2 x 6.0
50
System: IP 67 (2 mWS, 7 days)
Switchgear: 54
See name plate
S3-15 %/120 sec
60 (30 per pump)
20
22
10
16
19
9
3
See name plate
40 (briefly 3 min, 60°C)
3
40
40
1)
< 70 *
140
50
3000
185
830/755/630
1060
85
80
50, 100, 150
70
3,8T4
4,9T4
5,3T4
2 x 3.8
2 x 4.9
2 x 5.3
2 x 6.9
2 x 8.5
2 x 8.9
15
20
22
13
16
19
English
25