• Adjust the parameter by turning the special dial
ATTENTION: go on to point 9)
Slow ON-PULSE (TIG AC and DC))
3B)Press the "pulsation" button until the desired
function is working (the ON PULSE LIGHT is
flashing)
4B)Press the SET key until the GREEN led I
the RED led Ip will start flashing; adjust the
1st level PEAK CURRENT I
TIG DC: 5 ÷ 250 A
TIG AC: square wave 5 ÷ 250 A
5B)Press the SET key until the RED led of the
2nd level of PEAK CURRENT I
ing
TIG DC: 5 ÷ 250 A
TIG AC: square wave 5 ÷ 250 A
• Adjust the parameter by turning the special dial
6B)Press the SET key until the RED led of the 1 st
level BASIC CURRENT starts flashing
TIG DC: 5 ÷ 250 A
TIG AC: square wave 5 ÷ 250 A
1p
mixed wave 5 ÷ 250 A
sine wave 16 ÷ 176 A
starts flash-
2p
mixed wave 5 ÷ 250 A
sine wave 16 ÷ 176 A
mixed wave 5 ÷ 250 A
sine wave 16 ÷ 176 A
• Adjust the parameter by turning the special dial
7B)Press the SET key until the RED led of the
PEAK TIME t
TIG DC: 0,01 ÷ 0,99 sec
TIG AC: 0,10 ÷ 0,99 sec
and
1
• Adjust the parameter by turning the special dial
8B)Press the SET key until the RED led of the
BASIC TIME t
TIG DC: 0,01 ÷ 0,99 sec
TIG AC: 0,10 ÷ 0,99 sec
• Adjust the parameter by turning the special dial
ATTENTION: go to step 9)
EASY PULSE (only TIG DC)
3C)Press the "pulsation" button until the EASY
PULSE function is working
4C)Press the SET key until the GREEN led I
the RED led I
level PEAK CURRENT I
by turning the special dial.
24
starts flashing
p
starts flashing
b
will start flashing; adjust the 1
p
(5 ÷ 250 A); value
1p
and
1
st

Publicidad