Descargar Imprimir esta página

EINHELL HT 1600-F Instrucciones De Servicio página 14

Instrucciones de servicio

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
Anleitung HT 1600-1801-F
GB
Assembly drawing
1. On/Off switch
2. Connection cable with power plug
3. Water outlet
4. Water inlet + filter
5. Pistol
6. High-pressure hose
7. Lance
8. Foam spray attachment
5
7
Installation
14
09.11.2001 7:51 Uhr
6
8
Seite 14
1. The main switch has to be in „O" position
(item 1).
2. The water supply hose (item 2) has to be
connected to INLET (item 4). Use a hose
designed for a minimum capacity of 15 bar with
an inner diameter of at least 12-13 mm (1/2").
3. Fit the lance to the pistol.
4. Connect the high-pressure hose (item 5) to the
OUTLET (item 6) and to the pistol. The water
temperature should never exceed 50°C in
continuous operation.
5. Open the water tap (item 3).
6. Press the pistol trigger (item 7) until water
emerges from the lance nozzle and flushes out
any residues left in the line.
7. Insert the power plug in the socket-outlet
(item 8).
8. Switch on the machine by moving the switch to
„I" position. Starting is easier and the machine is
placed under less strain if you press the pistol
trigger before switching on.
Fitting the lance
The lance (item 1) is latched onto the spray pistol
(item 2) with the bayonet connector. Insert the lance
in the direction indicated by the arrow „A" and turn
approx. 15° clockwise until the two parts are fully
connected. The nozzle cleaning needle (item 4) can
be used to remove any dirt which may collect in the
nozzle. Caution! Before cleaning, switch off the
machine and disconnect from the water supply.

Publicidad

loading

Este manual también es adecuado para:

Ht 1800-fHt 1801-f41.406.5141.406.5041.403.5041.403.53