8 Maintenance and cleaning
8 Maintenance and cleaning
Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free operation.
The maintenance cycle is usually three months. If the device is operated for more than 8 hours a day, the
maintenance intervals should be changed as needed.
8.1 Maintenance and cleaning intervals
Authorized personnel must clean and inspect the device regularly. Any dirty device components that cannot
be cleaned adequately must be replaced. The dirty components must be placed in bags that are
impermeable (so dust cannot escape) and disposed of in accordance with regulatory stipulations. The
specified intervals are standard values and refer to single-shift operation. We recommend recording the
inspections. The date of the inspection, the detected defects and the name of the inspector must be observed.
Daily
Weekly
Monthly
9 Faults and troubleshooting
► Observe the documentation for the welding components.
► Observe the "Warranty" documentation.
Contact your retailer or ABICOR BINZEL in the event of questions or problems.
Tab. 3
Faults and troubleshooting
Fault
Test and gaging sleeves are
jammed
Torch does not fit into the
clamping body
10 Disassembly
Disassembly may be carried out only by a retailer.
Loosen and remove screws to disassemble the straightening unit, holder and torch seat.
1
Loosen the screws from the installation site and remove the WH Tandem alignment jig.
2
EN - 12
► Check that all threaded fittings are secure.
► Lightly oil the guides and test sleeve.
► Clean all parts.
Cause
Guides and test sleeve are
dirty
Clamping body is dirty
WH Tandem alignment jig
Troubleshooting
► Clean the guides and test
block.
► Clean all parts.