CYLINDER LABELING VERBIAGE
THIS CYLINDER IS TO BE USED WITH THE DeVILBISS iFILL PERSONAL
OXYGEN STATION. THIS CYLINDER CONTAINS 93+/-3% OXYGEN
PRODUCED BY THE DeVILBISS iFILL PERSONAL OXYGEN STATION
USING A PRESSURE SWING ADSORPTION PROCESS.
OXYGEN CYLINDERS FILLED BY THE DeVILBISS iFILL PERSONAL OXYGEN STATION SHALL BE USED
FOR PERSONAL USE ONLY. "NOT TO BE FILLED FOR RESALE"
WARNING: HIGH PRESSURE OXIDIZING GAS VIGOROUSLY ACCELERATES COMBUSTION.
CAUTION: For medical applications. Use only as directed by a licensed practitioner. Uninterrupted use of high concentrations of
oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful.
CAUTION: DO NOT HANDLE CYLINDER OR USE CONTENTS UNTIL YOU ARE TRAINED TO USE CYLINDER
AND CONTENTS, INCLUDING EMERGENCY PROCEDURES.
CAUTION: IMPROPER FILLING OR ABUSE OF THIS CYLINDER, OR FAILURE TO HEED THIS CAUTION MAY CAUSE SERI-
OUS INJURY OR LOSS OF LIFE. DO NOT ALTER OR MODIFY CYLINDER OR RELATED COMPONENTS. KEEP OUT OF
THE REACH OF CHILDREN.
Secure cylinder during storage and use. No smoking in cylinder area. Turn the regulator or conserver off after each use and when
empty. Use in accordance with the DeVilbiss iFILL Personal Oxygen Station instruction guide. Cylinder temperature should not
exceed 130°F (54°C). Keep away from heat, flame and spark. Do not drop.
"Use No Oil or Grease". KEEP CYLINDER, ALL EQUIPMENT AND CONNECTIONS FREE OF OIL AND GREASE
TO AVOID VIOLENT IGNITION.
TRANSFILLING OF THIS GAS IS PERFORMED BY THE DeVILBISS iFILL PERSONAL OXYGEN STATION ONLY.
Cylinders that have been refinished and/or exposed to elevated temperatures must be hydrostatically tested before filling. Do not
use caustic paint stripper or corrosive cleaners. Aluminum cylinders subject to the action of fire or heated to temperatures in
excess of 350°F (177°C) must be withdrawn from service and condemned by trained personnel. Valve and safety relief devices
must be removed and replaced by trained and authorized personnel. Do not alter or modify this cylinder in any way.
DO NOT REMOVE THIS PRODUCT LABEL
Not for Commercial Resale
A L U M I N U M H I G H P R E S S U R E G A S C Y L I N D E R
Improper use, filling, storage, or disposal may cause personal injury, death, or property damage. Do not alter or modify this cylinder
or valve in any way. Do not use caustic or corrosive cleaners. Never fill this cylinder unless it has been hydrostatically tested. Only
trained personnel should fill or service the cylinder. Only trained personnel should replace valves and pressure relief devices and only
with the complete assemblies containing the proper burst disc rating supplied by the valve manufacturer. Always secure cylinder in
a cool dry area, out of reach of children. Do not expose filled cylinder to temperatures above 130°F (54°C). Cylinders exposed to
fire or heat in excess of 350°F (177°C) must be condemned. Cylinders refinished or subjected to elevated temperatures must be
hydrostatically tested prior to refilling. Do not remove, alter, or obscure this warning label. Proper cleaning of cylinder, valve, and
components is required before filling with oxidizing gasses such as oxygen and nitrous oxide.
Service, maintain and inspect cylinders in accordance with C.G.A.pamphlet C-1, C-6.1, G-4, G-4.1, G-4.3, P-1, P-2, P-2.5, P-14, and
G-8.2 available from the CGA at ph. 703-788-2700 or web: www.cganet.com
SE-535-CYL
Sunrise Medical
Respiratory Division
100 DeVilbiss Drive
Somerset PA 15501
W A R N I N G
MADE IN U.S.A.
PIPER METAL FORMING CORPORATION
NEW ALBANY, MS
www.piperimpact.com
8
I M P O R TA N T PA R T S