Service tasks
3. In standby mode, use the cursor keys
"Free selection":
4. Press ENTER to confirm.
5. ASC2000RPA only: to significantly reduce the duration of the
evacuation process, "nitrogen test" can be deselected in the
default settings (see "Editing default values" on page 70).
6. Select "Vacuum phase ?" (see "Free selection" on page 87) and carry
out a vacuum phase with a duration of one minute.
7. Using the refrigerant draining station, WAECO item number
8885200059, empty the vehicle's air conditioning system
according to the instructions in the operating manual.
8.7
Correcting the filling quantity for long service hoses
If longer or shorter service hoses are required for the device, you need to
adjust the filling quantities to the new hose lengths.
The service hoses for the high and low pressure sides must always be
of the same length, as otherwise the filling quantities will not be correctly
measured.
1. In standby mode, use the cursor keys
"Other selections":
2. Press ENTER to confirm.
100
Short selection
Free selection
Other selections
ENTER-OK
Short selection
Free selection
Other selections
ENTER-OK
or
to select
or
to select
AirConServiceCenter