Service tasks
8.2
Changing the internal filter
1. In standby mode, use the cursor keys
"Free selection":
2. Press ENTER to confirm.
3. Skip the query requesting "Car data".
4. Select "Rec/Recycling phase ?".
5. Set the "Pressure increase Test time min." to "1".
Press ENTER to confirm.
6. Deselect "Vacuum phase ?" with "No".
Press ENTER to confirm.
7. Deselect "Filling phase?" with "No".
Press ENTER to confirm.
8. Select "Process start?".
Confirm with ENTER.
The service hoses are drained and the AirConServiceCenter is in
standby mode.
Switch off the device before opening it and pull out the mains plug.
9. Take off the front panel:
Undo the screws (D) on the control panel and lift it up. Then undo the
screws (E) on the bottom of the front panel and take it off.
94
Short selection
Free selection
Other selections
ENTER-OK
or
to select
AirConServiceCenter