Operation
If the refrigerant has been contaminated (analysis only possible with
ASC2000RPA), abort the air conditioning service and use the refrigerant
draining station, WAECO item number 8885200059, to drain the air
conditioning system.
ASC2000RPA only: if applicable, the message "NCG evacuation"
appears in the display (6) once the recycling phase has been completed.
Non-condensable gases (such as air or oxygen) are automatically
released into the surrounding air.
✓ After flushing is completed, the AirConServiceCenter goes into
standby mode.
19. If necessary, remove the adapter from the flushing circuit and
reconnect all the components to the refrigerant circuit.
Fit the connections of the AirConServiceCenter to the vehicle
air conditioning system and open them.
20. In standby mode, use the cursor keys
"Free selection":
21. Press ENTER to confirm.
22. If necessary, enter the desired data with the keypad (7) and press
ENTER to confirm.
If you do not want to enter any data here, press ENTER to advance
to the next program step.
23. Deselect "Rec/Recycling phase ?" with No (the chosen setting
flashes) and press ENTER to confirm.
24. Select "Vacuum phase ?" (the chosen setting flashes) and press
ENTER to confirm.
25. If necessary, enter the desired data with the keypad (7) and press
ENTER to confirm.
If you do not want to enter any data here, press ENTER to advance
to the next program step.
26. Select "Filling phase" (the chosen setting flashes) and press
ENTER to confirm.
90
Short selection
Free selection
Other selections
ENTER-OK
or
to select
AirConServiceCenter