Descargar Imprimir esta página

Waeco AirCon Service Center Instrucciones De Uso página 104

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Troubleshooting
10 Troubleshooting
Fault
The display shows
"
Warning !
Internal vessel
"
overpressure.
The display shows
"
Warning !
"
Inter. vessel filled.
The display shows
"
Warning !
Pressure inside the A/C
system
"
Recovery started!
The display shows
"
Warning !
Pressure inside the
"
A/C system
The display shows
"
Not enough vacuum.
"
Carry on?
The display shows
"
A/C system leakage!
"
Continue?
The display shows
"
Drained oil glass
"
emptying.
(ASC 2000, ASC 2000 RPA
and ASC 3000 only)
The display shows
"
Warning !
Not enough vacuum
"
for injection!
The display shows
"
Not enough refrigerant.
"
Add.
104
Cause
This message is normal
during the recycling process.
The internal refrigerant
container is too full to hold
the quantity to be extracted.
This message is normal at
the start of the vacuum
process. There is still
pressure present in the air
conditioning system.
Message during the vacuum
process. There is pressure in
the air conditioning system.
This message appears
during the vacuum process
when the pressure in the air
conditioning system after
8 minutes is still more than
50 mbar.
Message at the end of the
vacuum process. The air
conditioning system shows
a vacuum loss of more
than 120 mbar during the
checking time.
This message appears
during the extraction or
recycling process if there
is more than 150 ml of
used oil in the container.
This message appears
during the filling phase
if the vacuum in the air
conditioning system is
insufficient to end the
process.
This message appears
during the process input
if there is not enough
refrigerant in the internal
container to complete the
process.
Remedy
To continue, press ENTER
for three seconds.
If the message appears more
than once, inform a technician.
Drain the internal refrigerant
container in the proper
manner.
No action is required.
The process continues
automatically.
No action is required.
The process continues
automatically.
Check the air conditioning
system or the connections
between it and the
AirConServiceCenter
for leaks.
Check the air conditioning
system or the connections
between it and the
AirConServiceCenter
for leaks.
Dispose of the content of
the used oil container in an
environmentally responsible
manner.
Check the air conditioning
system or the connections
between it and the
AirConServiceCenter
for leaks.
Fill the refrigerant container.
AirConServiceCenter

Publicidad

loading

Este manual también es adecuado para:

Asc 1000Asc 2000Asc 2000 rpaAsc 3000