Changing the fi-
IMPORTANT! When fitting the Robacta Drive CMT flex (22° / 36°) fixing bracket,
xing bracket
ensure that the installation marker for the desired angle matches the installation
marker on the Robacta Drive CMT (TCP in 6th robot axis).
* Torque: 2,4 Nm
1
Replace Wear
Parts on Torch
Neck
Risk of scalding due to hot coolant.
This can result in serious personal injuries.
IMPORTANT! Do not allow coolant to leak out. Pay attention to the following
points when removing the pipe bend from the Robacta Drive coupling point:
-
-
-
-
AlMg
100-150N
2
1
CAUTION!
Turn mains switch on power source to - O - position prior to removing torch
neck.
Cut welding wire to length by the contact pipe
Press pipe bend in and hold it
Completely undo the swivel nut
With a quick movement, pull the pipe bend straight off
4
Fe, CrNi, CuSi
150-200N
2
1
°
2 2
2
*