TESTING THE NAILER
● Operators and others in work
Ordinary eyeglasses do not
provide adequate protection.
● Never use Nailer unless push lever is
operating properly.
Before actually beginning the nailing work, test the Nailer
by using the checklist below. Conduct the tests in the
following order.
If abnormal operation occurs, stop using the Nailer
and contact a metabo HPT authorized service center
immediately.
(1) DISCONNECT AIR HOSE FROM NAILER.
REMOVE ALL NAILS FROM NAILER.
□ ALL SCREWS MUST BE TIGHTENED.
If any screws are loose, tighten them.
□ THE PUSH LEVER AND TRIGGER MUST MOVE
SMOOTHLY.
Push Lever
12
DANGER
area
MUST
wear
glasses with side shields
which conforms to ANSI Z87.1
specifi cations.
WARNING
Trigger
Do not connect
air hose
(2) REMOVE ALL NAILS FROM NAILER.
DO NOT push or rest Push Lever against any surface.
DO NOT FORCE OR USE TOOLS TO OPERATE
SWITCH.
Select SINGLE SEQUENTIAL ACTUATION MODE
safety
according to the following steps.
Open the change stopper by pushing the bottom of
trigger.
Grasp the change rod between two fi ngers (one on
each side of the trigger) and slide it down (Single
Sequential Actuation Mode.)
Confi rm that the change stopper has completely
returned to original position inside the trigger.
(SINGLE SEQUENTIAL ACTUATION MECHANISM).
Grasp The
Change Rod
(3) Adjust the air pressure to 70 psi (4.9 bar 5 kgf/cm
Connect the air hose.
□ THE NAILER MUST NOT LEAK AIR.
Push The Change stopper
Position of
Change Rod
).