If nails are driven too deep, turn the adjuster to the
shallow side.
Adjustments are in half-turn increments.
Turn Adjuster
Too Deep
If nails are driven too shallow, turn the adjuster to the
deep side.
Turn Adjuster
Too Shallow
Stop turning the adjuster when a suitable position is
reached for a nailing test.
Connect the air hose.
ALWAYS WEAR EYE PROTECTION.
Perform a nailing test.
DISCONNECT AIR HOSE FROM NAILER.
Choose a suitable position for the adjuster.
RAFTER HOOK
With the NV83A5, an included hook can be attached by
using three M5
16 fl ange bolts which are included with
×
the tools. When the tool is detached from the hose and not
in use, the hook can be used to store the unit.
● When attaching or detaching the hook, make
sure the hose is detached and the nails are
removed from the tool.
Flush
Flush
WARNING
(1) How to attach the hook
Hexagonal bar wrench for M5
Main unit
Fig. 1
• When attaching, use a hexagonal bar wrench for M5
(separate).
• Fix the hook ( ) to the main unit in three locations
using the M5
16 fl ange bolts ( ) (Fig. 1).
×
Fastening Torque
8.3±0.5 N
m
6.1±0.4 ft.lbs
• The hook can be attached in any direction. Adjust the
hook according to the operating environment (Fig. 2).
(2) How to detach the hook
Detach the hook by reversing the aforementioned
steps for attaching the hook.
● When the hook is attached, operate only
with SINGLE SEQUENTIAL ACTUATION
MECHANISM
ACTUATION MECHANISM. For switching
between
SINGLE
CONTACT, see the appropriate section in
"METHODS OF OPERATION".
● Disconnect the air hose when hook the unit.
● Do not hook on high or unstable locations.
Also, do not hook it to the body, clothing, belt
or other personal items.
● When reassembling the trigger to a contact
actuation trigger while the hook already
attached, remove the hook.
English
Fig. 2
85±5 kgf
WARNING
and
not
with
CONTACT
SEQUENTIAL
cm
and
19