2.1 Technical data
Operating voltage
Weight without cable
Minimum material thick-
ness
Steel up to 400 N/mm
Maximum material thick-
ness
Steel up to 400 N/mm
Noise and vibration emission values
Vibration emission value
a
(vector sum of three di-
h
rections)
Uncertainty K for vibration
emission value
A-assessed sound pres-
sure level L
typically
PA
A-assessed sound power
level L
typically
WA
Uncertainty K for noise
emission values
2.2 Noise and vibration information
WARNING
Hearing damage if noise emission
value is exceeded
Wear hearing protection.
u
WARNING
Danger of injury if vibration emis-
sion value is exceeded
Select tools correctly and change
u
promptly in case of wear.
u
Specify additional safety measures to
protect the operator against the effect
of vibrations (e.g. keep hands warm,
organization of work processes, pro-
cessing with normal feed force).
Depending on the conditions of use and con-
dition of the power tool, the actual load can
be higher or lower than the specified mea-
surement.
F 300
(2A1)
230 V~ 50/60 Hz
120 V~ 50/60 Hz
5.5 kg / 12.1 lbs
0.75 mm / 0.030 in /
22 ga
2
1.25 mm / 0.049 in /
18 ga
2
≤ 2.5 m/s
2
1.5 m/s
80 dB (A)
91 dB (A)
3 dB
Translation of the original operator's manual
F 300
(3B1)
230 V~ 50/60 Hz
120 V~ 50/60 Hz
6.4 kg / 14.1 lbs
0.75 mm / 0.030 in /
22 ga
1.25 mm / 0.049 in /
18 ga
2
≤ 2.5 m/s
1.8 m/s
85 dB (A)
96 dB (A)
3 dB
The specified vibration emission value was
measured according to a standardized test
process and can be used to compare power
tools. It can also be used for a preliminary
estimation of the vibration load.
Times when the machine is switched off or is
running, but not actually in use, can signifi-
cantly reduce the vibration load during the
entire working period.
F 301
(2A1)
230 V~ 50/60 Hz
120 V~ 50/60 Hz
5.3 kg / 11.7 lbs
0.45 mm / 0.018 in /
36 ga
1 mm / 0.039 in /
20 ga
2
≤ 2.5 m/s
2
1.5 m/s
80 dB (A)
91 dB (A)
3 dB
EN
2
2
13

Publicidad

loading

Este manual también es adecuado para:

Trutool f 301