9. OPERATION
There are 4 heating methods:
Temperature mode
For controlled heating up to the desired
temperature and if you want to make use
of the thermostat feature. This feature
maintains the heated workpiece at the
pre-set temperature for a maximum
period of 5 minutes.
With the temperature or time mode
For controlled heating up to the desired
temperature or duration. Depending on
which of these is reached or elapsed first,
the heater switches off.
9.1 Selecting heating modes
The various heating modes can be selected by tapping the current mode on the settings screen.
26
Time mode
Suitable for series production. If the time
needed to reach a certain temperature is
known, the workpiece can be heated in
series with the time mode.
In the event of an emergency. If the sensor
is faulty, as a contingency measure, the
workpiece can be heated with the time
mode. The temperature may be measured
with an external thermometer.
With the temperature & speed mode
In the case of controlled heating to
the desired temperature, whereby a
maximum temperature gradient per time
unit can be entered so the workpiece is
heated according to a certain curve.