Descargar Imprimir esta página

DeWalt DPC17PS-QS Manual De Instrucciones Y Seguridad página 18

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 126
EN G LI SH
repair agent by contacting your local DEWALT office at
the address indicated in this manual. Alternatively, a list
of authorised DEWALT repair agents and full details of
our after-sales service and contacts are available on the
Internet at: www.2helpU.com.
TROUBLESHOOTING GUIDE
This section provides a list of the more frequently encountered malfunctions, their causes and corrective actions.
The operator or maintenance personnel can perform some corrective actions, and others may require the assistance
of a qualified DEWALT technician or your dealer.
Problem
Excessive air tank pressure-safety valve pops off
Air leaks
Air leaks in air tank or at air tank welds
Air leaks between head and valve plate
Air leaks from safety valve
Knocking Noise
Pressure reading on the regulated pressure gauge drops when an accessory is used
Compressor is not supplying enough air to operate accessories
Regulator knob has continuous air leak
Regulator will not shut off air outlet
Motor will not run
CODE
POSSIBLE CAUSE
Pressure switch does not shut off
1
motor when compressor reaches cut-
out pressure
2
Pressure switch cut-out too high
3
Tube fittings are not tight enough
4
Defective air tank
18
POSSIBLE SOLUTION
Set the On/Off switch to OFF (0), if the unit does not shut
off contact a DEWALT factory service center or a DEWALT
authorized service center.
Contact a DEWALT factory service center or a DEWALT
authorized service center.
Tighten fittings where air can be heard escaping. Check
fittings with soapy water solution. Do Not Overtighten.
Air tank must be replaced. Do not repair the leak.
m WARNING: Risk of bursting. Do not drill into, weld or
otherwise modify air tank or it will weaken. The air tank
can rupture or explode.
Code
1,2
3
4
5
6
6
7
8, 9, 10, 11, 12
13
13
11, 14, 15, 16, 17,
18, 19, 20

Publicidad

loading