Programming (continued)
Operating Modes
This operator is programmed to function in one of four
different operating modes. See the rest of this section for
more detailed information.
B2 MODE
Works with buttons on wall controller, myQ Facility®,
wired 3-Button Wall Controller, and 3-Button
Transmitter; momentary to open, stop,and close.
Works with Single Button Control and Single Button
Transmitter; momentary to open, stop, close, and
stop & reverse.
A Monitored Entrapment Protection device is
required to be connected for downward movement.
Monitored Entrapment Protection devices are Auto-
Learned or manually configured through the wall
control menu..
A Monitored Entrapment Protection device
activation will reverse the door to its Open limit. An
activated Monitored Entrapment Protection device
can be overridden with 5 seconds of constant
pressure on the Wall Control Close button.
Timer To Close is available in B2 Mode with two settings.
The user can select a desired Timer to Close (TTC) timer
under the Timers menu.
In B2 the Car Dealer feature is available. The Car Dealer
input (typically a treadle switch, loop detector, or motion
sensor) will open the door to mid-stop, and TTC will be
enabled. Repeated Car Dealer Input will not open the door
beyond the mid-stop and will reset the TTC timer. TTC
can be set either to one time close or timer secure
In B2 the All Fly feature is available. (FSTS Mode)
The All Fly input (typically a mushroom button) will
open the door to its Open limit, bypassing a mid-
stop, and TTC will be enabled.
The CLOSE button immediately closes the door.
The STOP button resets the TTC timer (held button
will pause, releasing the button will reset).
The OPEN button resets the TTC timer.
The controller will make infinite attempts to close
the door until the obstruction is cleared.
TTC will be enabled after Monitored Entrapment
Protection activation reverses the door to its Open
limit.
Timer Defeat Input will stop TTC timer
B2 / T ONE TIME CLOSE)
After the TTC timer elapses operator will close the
door.
TTC Timer will be active at the Open Limit or at a
defined mid-stop.
The CLOSE button immediately closes the door.
The STOP button cancels the TTC for that cycle (no
automatic motion).
The OPEN button resets the TTC timer.
TTC will be disabled if the door reverses from an
obstruction.
Timer Defeat Input will stop the TTC timer
B2 / TS (TIMER SECURE)
After TTC timer elapses operator will close door.
TTC Timer will be active anywhere above close limit.
The CLOSE button immediately closes the door.
The STOP button resets the TTC timer (held button
will pause, release resets)
The OPEN button resets the TTC timer.
LMEP activation resets the timer
TTC will be enabled after Monitored Entrapment
Protection device activation reverses the door to its
Open limit. The controller will make infinite attempts
to close the door until it reaches close limit.
Timer Defeat Input will stop the TTC timer
C2 MODE (DEFAULT)
Works with buttons on wall controller, wired
3-Button Wall Controller, and 3-Button Transmitter*;
momentary to open, stop, and constant pressure
to close.
Works with Single Button Control and Single Button
Transmitter*; momentary to open, stop, and stop &
reverse.
Works without a Monitored Entrapment Protection
device learned, but can operate if a Monitored
Entrapment Protection device is learned and
connected for downward movement.
Monitored Entrapment Protection device activation
will reverse the door to its Open limit. An activated
Monitored Entrapment Protection device can be
overridden with 5 seconds of constant pressure on
the Wall Control Close button.
*Constant Pressure to Close is not available from a