Battery Backup Wiring
NOTE: It's recommended to install battery backup unit at ground level, prior to mounting operator on fixed location.
1.
Remove the battery cover from the battery enclosure (see image 1).
2.
Ensure jumper and battery harness are properly routed and connected (see images 2 and 3).
3.
Using supplied screws, reinstall and secure battery box cover and ensure screws are tightened firmly (see image
1).
4.
Using supplied screws, mount battery enclosure to operator (OR) in an appropriate alternate location and ensure
screws are tightened firmly. (Reference the Recommended mounting location.)
5.
Route wires around backside of battery enclosure, through knock out and into electrical box. (Reference the
Knock out location.)
6.
Place snap in cord gland over top of wires and snap into place.
Recommended mounting location:
JHDC/JDC: Side of operator; opposite from drive shaft and sprocket location.
TDC: Mount to the bottom of the operator. Open electrical box and knock out appropriate backside ½
conduit location.
Knock out location:
JHDC/JDC: Bottom of the electrical box, adjacent to the EMI filter board.
TDC: Bottom of the electrical box, adjacent to the antenna AUX connection.
1
3
Red Wire =
Black Wire =
2
JHDC
WARNING
Observe Voltage
30
30
Replaceable 30A
DC Input from
Automotive Fuses
Transformer/Rectifier
(One pair for 700, two pairs for 1200)
7Ah Battery
Motor Power
4.5Ah Battery
WARNING
Observe Voltage
30
30
Replaceable 30A
DC Input from
Automotive Fuses
Transformer/Rectifier
(One pair for 700, two pairs for 1200)
18
4
TDC