Descargar Imprimir esta página

Kobalt SGY-AIR294 Manual Del Usuario página 17

Pistola rociadora con alimentación por sifón de aire y recipiente de aluminio de 946,36 ml

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING
SPRAY PATTERN/PROBLEM POSSIBLE REASON
Improper spray pattern
Improper spray pattern
Intermittent/
sputtering spray
Improper spray pattern
Unable to get round
spray
1) Atomization air pressure is
set too high.
2)Material too thin; fluid
adjustment turned in too far.
3)Fan pattern open too far.
1)Atomization air
pressure is set too
low.
2)Material too thick.
3)Fan pattern closed
too far.
1)Material level too low.
2)Container tipped too far.
3)Loose fluid inlet connection.
4)Needle seat loose/damaged.
5)Packing around needle
valve is dried out or loose.
6)Fluid nozzle loosely
installed, or dirt between
nozzle and body.
7)Clogged air vent.
1)Gun improperly
adjusted.
2)Dirty air cap.
3)Nozzle tip obstructed.
4)Sluggish needle.
Fan adjustment screw
not seating properly.
1)Reduce atomization air pressure.
2)Open fluid adjustment knob.
3)Partially close pattern adjustment
knob.
1) Reduce atomization air
pressure.
2) Thin to proper viscosity.
3) Partially open pattern
adjustment knob.
1) Refill.
2) Hold more upright.
3) Tighten.
4) Adjust or replace.
5) Lubricate/tighten.
6) Remove, clean, tighten.
7) Clean vent hole.
1)Re-adjust gun. Follow instructions
carefully.
2)Clean air cap.
3)Clean.
4)Lubricate.
Clean or replace adjustment screw.
17
SOLUTION

Publicidad

loading

Este manual también es adecuado para:

5091996