1.4. STOPPING AND TURNING OFF THE ROBOT
LAWN MOWER IN SAFE CONDITIONS
OBLIGATION:
Always switch off the robot lawn mower in safe
conditions before any cleaning, transport or
maintenance operation.
1. Press the "STOP" button (Fig. 1.A) to stop the robot lawn
mower safely and open the protective cover (Fig. 1.B).
2. Press the off button (Fig. 1.E) for a few seconds and wait
for the LED on the same button to go out.
3. Only after the LED has gone out (Fig. 1.E), remove the
safety key (Fig. 1.D) to switch off the robot lawn mower
in safe conditions.
4. The robot lawn mower is stopped or switched off in a
safe condition.
2.
INSTALLATION
WARNING:
Do not modify, tamper with, elude or eliminate
the safety devices installed.
NOTE: For further clarification on the installation of the
product please contact a STIGA dealer.
INSTALLATION COMPONENTS (Fig. 2)
(A) Charging base, (B) Power supply, (C) Perimeter cable,
(D) Perimeter cable fixing pegs, (E) Fixing screws for the
charging base, (F) Joint for perimeter cable, (G) Charging
base connectors
2.1. VERIFICATION OF THE INSTALLATION
REQUIREMENTS
2.1.1. GARDEN ASSESSMENT:
• Check the garden condition in accordance with Chap. 1.
• Level the ground to prevent puddles from forming after
a rainfall.
2.1.2. CHECKS FOR THE INSTALLATION OF THE
CHARGING BASE AND POWER SUPPLY:
ELECTRICAL HAZARD:
It is absolutely necessary to provide an
electrical outlet that complies with the relevant
laws of the country.
ELECTRICAL HAZARD:
The circuit provided must be protected by
a residual current device (RCD) with an
activation current not exceeding 30 mA.
ELECTRICAL HAZARD:
Do not connect the power supply to an
electrical outlet if the plug or the cable is
damaged.
Do not connect or touch a damaged cable
before it is disconnected from the power
supply.
A damaged cable can lead to contact with
live parts.
EN
1. Provide a flat surface at the edge of the lawn to position
the charging base.
2. Ensure that the distance of the base from any bends is
at least 200 cm.
WARNING:
The power cable, power supply unit, extension
cord and all other electric cables which do not
belong to the product must remain outside the
cutting area to maintain their distance from
hazardous moving parts and prevent damage
to cables which may come into contact with
live parts.
3. Set up the installation area of the power supply unit in
such a way as to prevent it from being submerged by
water under all weather conditions. Preferably install in a
closed room and protected from weather conditions, in a
location not easily accessible by unauthorised persons.
2.1.3. MAIN VERIFICATIONS FOR THE INSTALLATION
OF THE PERIMETER CABLE:
1. Check that the maximum slope of the work area is less
than or equal to 45% or 50% depending on the model
(see Par. 7 TECHNICAL DATA), and comply with the
rules shown in Fig. 3.
WARNING:
The robot can mow surfaces with a maximum
slope of 45% or 50% depending on the
model. In case of non-compliance with the
instructions, the robot may slip and exit the
work area
WARNING:
Areas with slopes higher than allowable
slopes cannot be mowed. Then place the
perimeter cable before the slope, excluding
that area of lawn from the mowing.
2. Check the entire work surface: assess the obstacles and
areas to be excluded from the work area, which must be
delimited with the perimeter cable.
2.2. CRITERIA FOR INSTALLING THE PERIMETER
CABLE
Following are the criteria used to install the perimeter cable,
for more detailed information please refer to the complete
instruction Manual.
MINIMUM DISTANCES
STRUCTURAL
ELEMENT
TYPE
Paving or driveway
at the same level as
the lawn
Moat or Walls
Hedge or plant with
protruding roots
3
MINIMUM INSTALLATION
DISTANCE
OF THE CABLE WITH RESPECT
TO THE STRUCTURAL
ELEMENT
SRSW01
SRBW01
5 cm
5 cm
35 cm
45 cm
30 cm
40 cm