 LED Indicators of the Emitter
Location
Indicator
Name
Color
Illuminated
Green
Code A is selected
Orange
Code B is selected
1
or
Scan code
C
CODE
Automatic interference prevention by wired synchroni-
OFF
zation being performed
LOCKOUT state. The indicator is illuminated in the
emitter of another sensor segment than that having a
or
2
Lockout
Red
E
ERR
lockout error (when in cascade connection or between
the emitter and receiver in the Wired Synchronization)
Green
Long Mode is selected
or
3
Operating range
L
LONG
OFF
Short Mode is selected
or
4
Test
Yellow
T
TEST
The target beams of the ABI are unblocked and the
Green
safety outputs are turned ON
Incident light level of the target beams of the ABI is
Area Beam
Orange
170% (factory default setting (*2)) or less of
---
ON-threshold (for 5 to 10 s)
5
Indicator (ABI)
(*1,*7)
Red
The target beams of the ABI are blocked
The target beams of the ABI are unblocked (The ABI
then will be illuminated in green when the safety
OFF
outputs are turned ON.)
Top-beam-state
6
TOP
Blue
The top beam is unblocked
(*1,*8)
Bottom-beam-sta
7
BTM
Blue
The bottom beam is unblocked
te (*1,*8)
 LED Indicators of the Receiver
Location
Indicator
Name
Color
Illuminated
Green
Code A is selected
or
Orange
Code B is selected
1
Scan code
C
CODE
Automatische interferentie voorkoming door bedrade
OFF
synchronisatie wordt uitgevoerd
LOCKOUT state. The indicator is illuminated in the
receiver of another sensor segment than that having a
2
Lockout
or
Red
E
ERR
lockout error (when in cascade connection or between
the emitter and receiver in the Wired Synchronization)
Green
Safety outputs are in ON state
or
3
O
OSSD
ON/OFF
Red
Safety outputs are in OFF state
LOCKOUT state due to a recoverable error (When in
Red
cascade connection, the indicator of only the sensor
segment having the error is illuminated)
or
M
MAINT
4
Maintenance
Safety outputs are instantaneously turned OFF due to
Orange
ambient light, vibration or noise. Or sequence error in
Muting, Pre-Reset or PSDI
Green
PNP is configured
5
or
PNP/NPN mode
P
PNP
OFF
NPN is configured
Fixed or Floating Blanking, Reduced Resolution,
Warning Zone or Slow mode of Response Time
6
or
Configuration
Green
F
CFG
Adjustment is enabled or after the Muting zone is
determined by the Dynamic Muting function.
7
or
Sequence
Yellow
INTERLOCK state
S
SEQ
The target beams of the ABI are unblocked and the
Green
safety outputs are turned ON
Incident light level of the target beams of the ABI is
Orange
170% (factory default setting (*2)) or less of
Area Beam
8
---
Indicator (ABI)
ON-threshold (for 5 to 10 s)
(*7)
Red
The target beams of the ABI are blocked
The target beams of the ABI are unblocked (The ABI
OFF
then will be illuminated in green when the safety
outputs are turned ON.)
Top-beam- state
9
TOP
Blue
The top beam is unblocked
(*8)
Bottom-
BTM
Blue
The bottom beam is unblocked
10
beam-state (*8)
*1. The indicator of the emitter is illuminated only in the case the Wired Synchronization is
enabled and is off in the case the Optical Synchronization is enabled.
*2. Configurable by SD Manager 3.
*3. This is the case for the Standard Muting mode. For other muting modes, refer to the
F3SG-SR User's Manual.
*4. The Area Beam Indicator closer to the "TOP" mark on the F3SG-SR blinks.
*5. The Area Beam Indicator closer to the "BTM" mark on the F3SG-SR blinks.
LED Indicators
Blinking
---
LOCKOUT state. The indicator is illuminated in the emitter of a sensor
segment having a lockout error
LOCKOUT state due to Operating range selection setting error
---
---
External Test is being performed
MUTING or OVERRIDE state.
In the MUTING state, only the ABI indicators in the muting zone are
blinking. Or the target beams of the ABI are blocked instantaneously
Incident light level of the target beams of the ABI is 170% (factory default
setting (*2)) or less of ON threshold 5 to 10 s after illuminated when incident
light level of the target beams of the ABI is 170% (factory default setting (*2))
or less of ON threshold. Or one muting input becomes the ON state and the
MUTING state has not been started yet, or one muting input becomes the
OFF state and the other is not in the OFF state yet. (*3)
LOCKOUT state due to Cap error or Other sensor error (*4), or Lockout
state due to DIP Switch setting error (*5*6)
---
MUTING/OVERRIDE state, or LOCKOUT state due to Cap error or Other
sensor error
MUTING/OVERRIDE state, or LOCKOUT state due to DIP Switch setting
error (*6)
Blinking
---
LOCKOUT state. The indicator is illuminated in the receiver of a sensor
segment having a lockout error
---
LOCKOUT state due to Safety Output error, or error due to abnormal
power supply or noise
LOCKOUT state due to a replacement- recommended error (When in
cascade connection, the indicator of only the sensor segment having the
error blinks)
Intelligent Tap is in the LOCKOUT state
Polarity of PNP is changed to NPN, or vice versa, during operation, and
internal circuit is defective
---
TEACH-IN mode, zone measurement being performed by Dynamic Muting,
or LOCKOUT state due to Blanking monitoring error, Configuration error or
Parameter error
Sequence or sequence error in Muting, Pre-Reset or PSDI (*9) or Teach-in error
MUTING or OVERRIDE state. In the MUTING state, only the ABI indicators
in the muting zone are blinking. Or the target beams of the ABI are blocked
instantaneously
Incident light level of the target beams of the ABI is 170% (factory default
setting (*2)) or less of ON threshold 5 to 10 s after illuminated when
incident light level of the target beams of the ABI is 170% (factory default
setting (*2)) or less of ON threshold. Or one muting input becomes the ON
state and the MUTING state has not been started yet, or one muting input
becomes the OFF state and the other is not in the OFF state yet. (*3)
LOCKOUT state due to Cap error or Other sensor error (*4), or LOCKOUT
state due to DIP Switch setting error (*5*6)
---
MUTING/OVERRIDE state, or LOCKOUT state due to Cap error or Other
sensor error
MUTING/OVERRIDE state, or LOCKOUT state due to DIP Switch setting
error (*6)
*6. DIP switches is on the Intelligent Tap.
*7. F3SG-SRB is not supported.
*8. F3SG-SRB is only supported.
*9. Refer to the F3SG-SR User's Manual for more information on blinking patterns.
Note: In the SETTING state to make settings with the SD Manager 3, the TEST, LONG
and CODE indicators on the emitter and the CFG, PNP and CODE indicators on the
receiver blink. (TEST: Yellow, LONG/CODE: Green, CFG/PNP/CODE: Green)

Publicidad

loading

Este manual también es adecuado para:

F3sg-2srb0160-14F3sg-2srb0160-25F3sg-2srb0240-14F3sg-2srb0240-25F3sg-2srb0240-45F3sg-2srb0280-85 ... Mostrar todo