INSTRUCTION FOR USE
TROUBLESHOOTING
Trouble
The motors do not work; no
warning light turns on.
Press one-start button S3,
Indicator light flashes and
power indicator light is on.
The brushes do not work, the
red warning light is on.
The recovery water vacuuming
is insufficient.
The solution flow to the
brushes is insufficient.
The squeegee leaves marks on
the floor.
Power indictor lights are all on.
NOTE
Machine with battery charger installed, cannot operate if the charger is not on board. In case of battery charger
malfunction, contact an authorized Service Center.
For further information refer to the Service Manual, available at any Service Center.
SCRAPPING
Scrap the machine by the qualified waste treatment institution.
Before the machine is scrapped, please take away and segregate below subassembly that relevant laws and regulations request must be
disposed in appropriate way.
Battery
-
-
Brush/Pad-holder
-
Plastic hose and plastic parts
Electrical and electronic components (*)
-
(*)
Please contact our company service center destroying any electrical and electronic components.
Machine material composition and recyclability
Electric motors-various
Plastic-non-recyclable material
Plastic-recyclable material
Probable causes
The battery connector is disconnected.
The batteries are completely discharged.
Brush motor overload, Vacuum motor overload.
Foreign materials (tangled threads, etc.) which may
prevent the brush from rotating.
The batteries are discharged.
The recovery water tank is full.
The hose is disconnected from the squeegee.
The vacuum grid is clogged, or the float is
stuck closed.
The squeegee is dirty or the squeegee blades
are worn or damaged.
The tank cover is not properly closed, or the gasket
is damaged, or the Bend tube is clogged.
The recovery water tank is dirty.
The solution/clean water filter is dirty.
There are debris under the squeegee blades.
The squeegee blades are worn, chipped or torn.
The squeegee has not been adjusted with the knob.
High battery Voltage.
Type
Aluminium
Ferrous materials
Wiring harness
Liquids
Rubber
Recyclable per-
centage
weight percentage%
100%
29%
100%
80%
100%
0%
100%
20%
25
ENGLISH
Remedy
Connect the battery connector.
Charge the batteries.
Use less aggressive brushes, check if vac-
uum motor or brush motor is in working.
Clean the brush hub.
Charge the batteries.
Empty the tank.
Connect.
Clean the grid or check the float.
Clean and check the squeegee.
Close the cover correctly or replace the
gasket or clean the Bend tube.
Clean.
Clean the filter.
Remove the debris.
Replace the blades.
Adjust.
Choose suitable battery voltage.
SC370 17B
2%
23%
32%
1%
0%
1%
38%
3%