Descargar Imprimir esta página

Ingersoll Rand QE5-15A Información Del Producto página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

6
APPENDIX
6.1
DECOMMISSIONING
Routine Decommissioning
Routine decommissioning includes, for example, decommissioning
for maintenance work.
1. Lockout and Tagout.
2. Close the shutoff valves between the compressor and the
compressed air network.
3. Relieve the pressure in the aftercooler by carefully opening
the pressure relief valve.
Decommissioning for an Extended Period of Time.
For decommissioning for more than six months, contact Ingersoll
Rand distributor.
Final Decommissioning
In order to prevent renewed commissioning of the compressor or
misuse by unknown persons, the compressor must be rendered
unusable.
The compressor is made unusable by removing the electronic
controller.
6.2
CONSUMABLES AND AUXILIARY MATERIALS
The compressor oil capacity is approximately:
MODEL
2475
2545
7100
Safety Data Sheets
When handling consumables and auxiliary materials, the associated
Safety Data Sheets must be adhered to.
NOTICE
The following aspects must be taken into account for storage of
storing compressors:
The compressor should be stored in a dry building which should
be heated if possible. This is particularly true during the months
of winter.
The coolant is to be completely drained where there is a risk of
frost (t < 1°C (34°F) (compressor stage, coolers, system containers,
water filters, storage containers, lines, and valves).
47794362 Rev.A
RELEASED 02/Nov/2023 21:18:09 GMT
CRANKCASE CAPACITY
41 oz. (1212 ml.)
73 oz. (2158 ml.)
80 oz. (2365 ml.)
6.3
DISASSEMBLY
WARNING
Damage to health
Risk of damage to health from consumables and
auxiliary materials.
Consumables and auxiliary materials can cause
irreparable damage to health, induce allergies, or
irritate mucous membranes.
Follow the locally applicable operating instructions
and hazardous material Safety Data Sheets when
handling consumables and auxiliary materials
Avoid direct contact with consumables and
auxiliary materials. Wear personal protective
equipment.
In case of injuries associated with consumables and
auxiliary materials, consult a physician and indicate
the material involved.
Keep the Safety Data Sheet for the causative
material available.
CAUTION
Slip hazard
Slip hazard due to spilled consumables.
Clean up escaped consumable materials
immediately.
Avoid direct contact with consumables. Wear
personal protective equipment.
Prerequisites
The compressor is shut down.
The compressor is electrically disconnected.
The main disconnect switch is switched to OFF and secured
against restarting.
The compressor is not pressurized.
Liquids and greases are removed to the greatest extent
possible.
DANGER
Electric shock
Deadly electrical voltage.
Work on the electrical equipment may be
performed only by authorized electrical
technicians.
1. Disconnect the feed cables. See wiring diagram.
2. Remove the feed cables.
3. Apply seal plugs to the feed line openings.
Removing the Pipework
1. Disconnect the compressed air connection.
2. Disconnect the condensate drain lines.
3. Allow the condensate to drain out completely.
4. Clean up any escaped condensate immediately.
EN-15

Publicidad

loading

Este manual también es adecuado para:

247525457100