TRANSPORT AND INSTALLATION OF THE wELDING MACHINE

The transport position must be as indicated on the packaging. Impacts should be avoided during transport of the ma-
chine. The machine must be located in a dry and well-ventilated area, away from water outlets and from the welding
station (to prevent metal dust entering the welding machine). The machine must be installed on a horizontal surface
with a maximum gradient of 10°. The machine must be connected to an electrical box, which should consist of a cir-
cuit breaker and an automatic switch. The circuit breaker protects people from direct or indirect contacts with electri-
cal parts. The automatic switch must be chosen according to the equipment nameplate. A switch with an
intensity/time ratio of the slow type (D curve) is recommended to prevent false triggering.
HANDLING OF THE MACHINE
To handle the power unit, always use the front and rear handles. If you have the UTS 200 transport unit, check that
all couplings are properly fixed. To handle the machine once it is located in the transport unit, DO NOT use the upper
handles of the power unit. Handle the whole machine using the eye bolts screwed to the base of the transport unit.

DESCRIPTION OF THE ITEMS OF EQUIPMENT

1 - Control panel
2 - Positive pole connector
3 - Gas connector for TIG torch
4 - TIG torch connector or remote control in MMA mode
5 - Negative pole connector
6 - Main switch
7 - Connection to three-phase power network
8 - 2A Fuse (control)
9 - Remote control in TIG mode
10 - Gas Input
SOLTER