Autoranging Multimeter/English
SPECIFICATIONS
The instrument complies with:
EN61010-1.
Insulation:
Class2, Double insulation.
Overvoltage category:
CATIII 600V
Display:
2000 counts LCD display with function indication.
Polarity:
Automatic, (-) negative polarity indication.
Overrange:
"OL" mark indication.
Low battery indication:
The "BAT" is displayed when the battery voltage
drops below the operating level.
Measurement rate:
2 times per second, nominal.
Auto power off:
Meter automatically shuts down after approx. 15
minutes of inactivity.
Operating environment:
0 °C to 50 °C (32 °F to 122 °F) at < 70 %
relative humidity.
Storage temperature:
-20 °C to 60 °C (-4 °F to 140 °F) at < 80 % relative
humidity.
For inside use, max height:
2000m
Pollution degree:
2
Power:
One 9V battery , NEDA 1604, IEC 6F22.
Dimensions:
150 (H) x 70 (W) x 48 (D) mm
Weight:
Approx.: 255g.
Accuracy is given at 18 °C to 28 °C (65 °F to 83 °F), less than 70 % RH.
4
Measurement
Application
Category
Measurements on circuits not directly connected to mains.
Examples include: Measurements on battery powered
Ⅰ
equipment and specially protected (internal) mains-derived
circuits.
Measurements on circuits directly connected to the low
voltage installation.
Ⅱ
Examples include: Household appliances, portable tools and
similar equipment.
Measurements performed in the building installation.
Examples include measurements on distribution boards,
Ⅲ
junction boxes, socket-outlets and wiring and cables in the
fixed installation.
Measurements performed at the source of the low-voltage
installation. Examples include measurements on primary
Ⅳ
overcurrent protection devices and electricity Instruments
DC Voltage
(Auto-ranging)
Range
Resolution
200.0mV
0.1mV
2.000V
1mV
20.00V
10mV
200.0V
100mV
600V
1V
Input Impedance: 10MΩ
Maximum Input: 600V dc rms.
Autoranging Multimeter/English
Accuracy
+0.5% of rdg + 2 dgts
+1.0% of rdg + 2 dgts
+1.2% of rdg + 2 dgts
5